Commands Execution
ViewCheck on ATCA-9405 Installation and Use (6806800S51E)
73
4.4.5 set-poll-interval-default
set-poll-interval-default command is used to reset the Poll interval value to default
value of a particular monitor.
Syntax for CLI
set-poll-interval-default monitorId <Monitor ID> deviceInstance
<Dev Instance>
Syntax for XML
<Script>
<InvokeMethod>
<Object>
<Class>deviceCategory</Class>
<Name>SP_VEE0-{Dev Cat}</Name>
</Object>
<Method>setPollIntervalDefault</Method>
<Argument>
<Name>deviceInstance</Name>
<Value>Dev Instance</Value>
</Argument>
<Argument>
<Name>monitorId</Name>
<Value>Monitor ID</Value>
</Argument>
</InvokeMethod>
</Script>]]>]]>
Dev Instance Enum Use list-device-instances CLI command to get the
equivalent enumerated value of supported Device
Instance
PollInterval Value Integer Type the Poll interval value for the specified monitor ID
Table 4-19 set-poll-interval
Argument Data Type Description