4.4.3 start-monitor
start-monitor command allows you to trigger a specific monitor to start monitoring if it
is not already initiated by default.
Syntax for CLI
start-monitor monitorId <Monitor ID> deviceInstance <Dev Instance>
Syntax for XML
<Script>
<InvokeMethod>
<Object>
<Class>deviceCategory</Class>
<Name>SP_VEE0-{Dev Cat}</Name>
</Object>
<Method>startMonitor</Method>
<Argument>
<Name>deviceInstance</Name>
<Value>Dev Instance</Value>
</Argument>
<Argument>
<Name>monitorId</Name>
<Value>Monitor ID</Value>
</Argument>
</InvokeMethod>
</Script>]]>]]>
The following table provides the Start-monitor command arguments.
Table 4-18 start-monitor
Argument Data Type Description
Monitor ID Integer Type the unique ID of the Monitor that you want to start
Dev Instance Enum Use list-device-instances CLI command to get the
equivalent enumerated value of supported Device
Instance