Commands Execution
ViewCheck on ATCA-9405 Installation and Use (6806800S51E)
63
4.3 Test Management and Control Commands
The following list of CLI commands are used for test management and control of diagnostic
tests.
4.3.1 start-test
start-test command allows you to start and run a particular diagnostic test.
Syntax for CLI
start-test testId <Test ID> deviceInstance <Dev Instance> arguments
-t <timeout-val> -Iterations <Itr-num> -Halt-onerror <halt-string>
Syntax for XML
<Script>
<InvokeMethod>
<Object>
<Class>deviceCategory</Class>
<Name>SP_VEE0-{Dev Cat}</Name>
</Object>
<Method>startTest</Method>
<Argument>
<Name>deviceInstance</Name>
<Value>Dev Instance</Value>
</Argument>
<Argument>
<Name>testId</Name>
<Value>Test ID</Value>
</Argument>
<Argument>
<Name>arguments</Name>
Execute all test management and control commands only after entering a specific device
category.