Page view 74
Commands Execution
ViewCheck on ATCA-9405 Installation and Use (6806800S51E)
75
The following table provides the stop-monitor command arguments.
4.4.7 set-rate
set-rate command sets the rate of change value for network monitors.
Syntax for CLI
set-rate monitorId <Monitor Id> deviceInstance <Dev Instance> rate
<Rate>
Syntax for XML
<Script>
<InvokeMethod>
<Object>
<Class>deviceCategory</Class>
<Name>SP_VEE0-{Dev Cat}</Name>
</Object>
<Method>setRate</Method>
<Argument>
<Name>deviceInstance</Name>
<Value>Dev Instance</Value>
</Argument>
<Argument>
<Name>monitorId</Name>
<Value>Monitor ID</Value>
</Argument>
<Argument>
<Name>rate</Name>
Table 4-21 stop-monitor
Argument Data Type Description
Monitor ID Integer Type the unique ID of the Monitor that you want to stop
monitoring
Dev Instance Enum Use list-device-instances CLI command to get the
equivalent enumerated value of supported Device
Instance