Using HPI-B
System Management Interface Based on HPI-B (Centellis 2000 R3.0/4411) User’s Guide (6806800P20C)
83
Synopsis
hpicooling [-h][-d domain_id] [-m cooling_mode]
Parameters
-h
help
-d domain_id
Use domain domain_id
-m mode
Set cooling mode
1: Internal cooling management enabled (default)
2: Internal cooling management disabled (cooling must be done manually via HPI controls in
this case)
4.6.2.2 Controlling Fan Speed via Linux Example Program
If the internal cooling management is switched off, you can control the fan speed via the Linux
example tool hpifan. Its usage is described in the following.
Description
Sets the fan speed for all fans of a specified domain.
Synopsis
hpifan [-h] [-d domain_id] [-s fan_speed_level]
Parameters
-h
help
-d domain_id