Using HPI-B
System Management Interface Based on HPI-B (Centellis 2000 R3.0/4411) User’s Guide (6806800P20C)
48
The RDR and the HPI control are defined as follows.
Table 4-3 Domain Management Control RDR
SaHpiRdrT Value
RecordId Assigned by HPI
RdrType SAHPI_CTRL_RDR
Entity The same entity like Domain Management
Resource
RdrTypeUnion Define in Table 4-4.
IdString MOTHPI_CTRL_NAME_DOMAIN_MANAGEMENT
Table 4-4 Domain Management Control
SaHpiCtrlRecT Value
Num MOTHPI_CTRL_NUM_DOMAIN_MANAGEMENT
Ignore SAHPI_FALSE
OutputType SAHPI_CTRL_OEM
Type SAHPI_CTRL_TYPE_OEM
TypeUnion - Oem -Mld MOTHPI_MANUFACTURER_ID_MOTOROLA
TypeUnion - Oem -ConfigData 0
TypeUnion - Oem - Default - Mld 0
TypeUnion - Oem - Default -
BodyLength
0
TypeUnion - Oem - Default - Body 0
Oem 0
Table 4-5 Domain Management Control State
SaHpiCtrlStateT Value
Type SAHPI_CTRL_TYPE_OEM
StateUnion - Oem - Mld MOTHPI_MANUFACTURER_ID_MOTOROLA
StateUnion - Oem - BodyLength Depends on the length of the resource name
Comments to this Manuals