Artesyn System Management Interface Based on HPI-B (Centel User Manual Page 54

  • Download
  • Add to my manuals
  • Print
  • Page
    / 136
  • Table of contents
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 53
Using HPI-B
System Management Interface Based on HPI-B (Centellis 2000 R3.0/4411) User’s Guide (6806800P20C)
54
If the domain/shelf specified in the call exists, the domain/shelf is removed, an HPI domain
removed event is generated and any sessions that may be open to this domain are closed.
Furthermore the domain shelf resource in the HPI domain is removed and a hot swap even of
type "NOT_PRESENT" is generated.
4.5 Artesyn Extensions
The following describes features which are not specified in the HPI-B specifications, but were
added by Artesyn or which are specific to the Artesyn HPI-B implementation..
4.5.1 HPI Controls for Domain and Shelf Management
This refers to the Domain Management Resource and Shelf Management Resource which were
previously explained. Both are Artesyn-specific extensions. See Working with the Multishelf
Library on page 43.
4.5.2 IPMI System Boot Options Support
A FRU may have a payload which is capable of booting an operating system (OS). Usually, a
boot firmware, such as BIOS or U-Boot, is started after the payload is powered up or reset. Via
the System Boot Options Control you can set some options for the boot firmware. The boot
firmware will read these settings from the IPMC.
In order to set or get the system boot options, you need to use the HPI Boot Option control.
CtrlState Pointer to control state as described in Table
"Domain Management Control State" on page 48.
In this control state, fill the field body as follows:,
[0] : 2 (stands for "remove domain")
[1] - [4] : IP address of shelf you want to add
(little endian order)
[5] - [6] : port of shelf (little endian order)
[7] - [n]: Domain name
Parameter Value