Artesyn System Management Interface Based on HPI-B (Centel User Manual Page 71

  • Download
  • Add to my manuals
  • Print
  • Page
    / 136
  • Table of contents
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 70
Using HPI-B
System Management Interface Based on HPI-B (Centellis 2000 R3.0/4411) User’s Guide (6806800P20C)
71
4.5.11 IPMI Command Control
IPMI command control is used to execute IPMI commands on a given resource id. This control
is created for all the FRUs in the shelf. hpiipmi client application makes use of this control to
get the IPMI commands executed.
RdrTypeUnion.CtrlRec.WriteOnly SAHPI_FALSE
RdrTypeUnion.CtrlRec.Oem Assigned by HPI implementation.
RdrTypeUnion.CtrlRec.IdString MOTHPI_CTRL_NAME_HPI_RESTART
_DAEMON
Table 4-32 HPI Restart Daemon State
SaHpiCtrlStateT Value
Type SAHPI_CTRL_TYPE_DIGITAL
StateUnion.Digital SAHPI_CTRL_STATE_PULSE_ON |
SAHPI_CTRL_STATE_OFF
Table 4-31 HPI Restart Daemon RDR (continued)
SaHpiRdrT Value
Table 4-33 IPMI Command RDR
SaHpiRdrT Value
RecordId Assigned by HPI implementation
RdrType SAHPI_CTRL_RDR
Entity Entity path of the FRU
Ex: {ADVANCEDTCA_CHASSIS,6}{FAN_TRAY_SLOT,1}
{COOLING_UNIT,1}
RdrTypeUnion Defined in next table
IdString MOTHPI_CTRL_NAME_BOOT_OPTION
Page view 70
1 2 ... 66 67 68 69 70 71 72 73 74 75 76 ... 135 136

Comments to this Manuals

No comments