Artesyn System Management Interface Based on HPI-B (Centel User Manual Page 70

  • Download
  • Add to my manuals
  • Print
  • Page
    / 136
  • Table of contents
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 69
Using HPI-B
System Management Interface Based on HPI-B (Centellis 2000 R3.0/4411) User’s Guide (6806800P20C)
70
4.5.10 HPI Restart Daemon Control
HPI Restart Daemon control enables the user to restart the hpi-b daemon.
hpirestartdaemon client application makes use of this control to restart the daemon.
RdrTypeUnion.CtrlRec.IdStri
ng
MOTHPI_CTRL_FAILED_SLOT_RESTOR
E_NAME
Table 4-30 Failed Slot Restore Control states
SaHpiCtrlStateT Value Notes
Type SAHPI_CTRL_TYPE_DIGITAL
StateUnion.Digital SAHPI_CTRL_STATE_PULSE_ON |
SAHPI_CTRL_STATE_OFF
Table 4-29 Failed Slot Restore Control RDR (continued) (continued)
SaHpiRdrT Value Notes
Table 4-31 HPI Restart Daemon RDR
SaHpiRdrT Value
RecordId Assigned by HPI implementation
RdrType SAHPI_CTRL_RDR
Entity Entity path of 'Daemon Resource'
Ex:
{ADVANCEDTCA_CHASSIS,6}
{SYS_MGMNT_SOFTWARE,0}
RdrTypeUnion.CtrlRec.Num MOTHPI_CTRL_NUM_HPI_RESTART_
DAEMON
RdrTypeUnion.CtrlRec.Type SAHPI_CTRL_TYPE_DIGITAL
RdrTypeUnion.CtrlRec.OutputType SAHPI_CTRL_GENERIC
RdrTypeUnion.CtrlRec.TypeUnion.Digital.De
fault
SAHPI_CTRL_STATE_OFF
RdrTypeUnion.CtrlRec.DefaultMode.Mode SAHPI_CTRL_MODE_MANUAL
RdrTypeUnion.CtrlRec.DefaultMode.ReadOnly SAHPI_TRUE
Page view 69
1 2 ... 65 66 67 68 69 70 71 72 73 74 75 ... 135 136

Comments to this Manuals