Artesyn System Management Interface Based on HPI-B (Centel User Manual Page 64

  • Download
  • Add to my manuals
  • Print
  • Page
    / 136
  • Table of contents
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 63
Using HPI-B
System Management Interface Based on HPI-B (Centellis 2000 R3.0/4411) User’s Guide (6806800P20C)
64
4.5.7 Active and Stand-By HPI Daemon Sensor
The Artesyn HPI-B implementation provides two sensors which allow to detect which of the
two HPI daemons in a system is the currently active, and which is the currently deactivated
one. There are two sensors: one which represents the currently active HPI daemon, and one
which represents the currently deactivated daemon. Both sensors are Artesyn OEM sensors,
but the structure of their RDR is similar to the RDR of the standard Active and Standby Shelf
Manager sensors which are described in the HPI-to-AdvancedTCA mapping specification.
Both Sensors are logical Sensors which do not have counterparts in the IPMI or AdvancedTCA
realm. Applicable events and readings are generated by the HPI implementation.
Both Sensors are modeled as Presence Sensors.
Table 4-23 HPI Daemon Redundancy Sensor Event State
MotHpiEventStateT Value Notes
EventState SAHPI_ES_FULLY_REDUNDANT |
SAHPI_ES_NON_REDUNDANT_SUFFICIENT_RESOURC
ES
Table 4-24 Active and Stand-By HPI Daemon Sensors RDRs
SaHpiRdrT Value Notes
RecordId Assigned by HPI implementation
RdrType SAHPI_SENSOR_RDR
Entity Same as Virtual Shelf Manager
Resource
IsFru SAPHI_FALSE Per the rules
stated in [HPI], the
IsFru flag is not
applicable when
the
ManagementInstr
ument is directly
associated with
the Resource, as is
the case here.
Page view 63
1 2 ... 59 60 61 62 63 64 65 66 67 68 69 ... 135 136

Comments to this Manuals