Using HPI-B
System Management Interface Based on HPI-B (Centellis 2000 R3.0/4411) User’s Guide (6806800P20C)
62
IsFru SAPHI_FALSE Per the rules
stated in [HPI],
the IsFru flag is
not applicable
when the
Management
Instrument is
directly
associated with
the Resource, as
is the case here.
RdrTypeUnion.SensorRec.Num MOTHPI_SENSOR_NUM_DAEMO
N_REDUNDANCY
RdrTypeUnion.SensorRec.Type SAHPI_OPERATIONAL
RdrTypeUnion.SensorRec.Catego
ry
SAHPI_EC_REDUNDANCY
RdrTypeUnion.SensorRec.Enable
Ctrl
True if the HPI User can enable or
disable the Sensor via
saHpiSensorEnableSet()
RdrTypeUnion.SensorRec.EventC
trl
SAHPI_SEC_PER_EVENT |
SAHPI_SEC_READ_ONLY_MAS
KS | SAHPI_SEC_READ_ONLY
RdrTypeUnion.SensorRec.Events SAHPI_ES_FULLY_REDUNDAN
T |
SAHPI_ES_NON_REDUNDANT_
SUFFICIENT_RESOURCES |
SAHPI_ES_NON_REDUNDANT_
INSUFFICIENT_RESOURCES
RdrTypeUnion.SensorRec.DataFo
rmat.IsSupported
SAHPI_FALSE
RdrTypeUnion.SensorRec.DataFo
rmat.ReadingType
Not Applicable
RdrTypeUnion.SensorRec.DataFo
rmat.BaseUnits
Not Applicable
RdrTypeUnion.SensorRec.DataFo
rmat.ModifierUnits
Not Applicable
Table 4-21 HPI Daemon Redundancy Sensor RDR (continued)
MotHpiRdrT Value Notes
Comments to this Manuals