Page view 48
Using HPI-B
System Management Interface Based on HPI-B (Centellis 2000 R3.0/4411) User’s Guide (6806800P20C)
49
4.4.3.2 Shelf Management Resource
The shelf management resource represents one daemon. For each configured daemon, the
default domain creates one shelf management resource. The shelf management resource is
defined as follows.
StateUnion - Oem - Body Sequence of n bytes, named [0] ... [n], with the
following definitions:
[0] - Command
0 = Get state
1 = Create domain (for set state)
2 = Remove domain (for set state)
[1] - [4] - IP address (little endian order)
[5][6] - port (little endian order)
[7] ... [n] - Domain name as null-terminated
string.
Table 4-5 Domain Management Control State (continued)
SaHpiCtrlStateT Value
Table 4-6 Shelf Management Resource
SaHPIRptEntryT Value
EntryId Assigned by HPI
ResourceId Assigned by HPI
resourceInfo 0 for all values
ResourceEntity {SYS_MNGMT_SOFTWARE domain Id}
ResourceCapabilities SAHPI_CAPABILITY_RESOURCE |
SAHPI_CAPABILITY_RDR |
SAHPI_CAPABILITY_CONTROL |
SAHPI_CAPABILITY_SENSOR
When the shelf is reachable:
SAHPI_CAPABILITY_DOMAIN
ResourceSeverity SAHPI_MAJOR
DomainId Domain Id when the shelf is reachable
IdString Domain name