Controls, LEDs, and Connectors
MVME2502 Installation and Use (6806800R96E)
76
3.4.2.5 XMC Connector (XJ1)
The MVME2502 supports two XMC sites. The board only support J15 for XMC site 1 and J25 for
XMC site 2.
16 GND
Table 3-14 COP Header (P50) (continued)
Pin Signal Description
Table 3-15 XMC Connector (XJ1) Pin out
Pin Row A Row B Row C Row D Row E Row F
1 RX0 + RX0 - +3.3V NC NC +3.3V
2 GND GND JTAG TRST GND GND HRESET
3 NC NC +3.3V NC NC +3.3V
4 GND GND JTAG TCK GND GND MRSTO
(PULLED UP)
5 NC NC +3.3V NC NC +3.3V
6 GND GND JTAG TMS GND GND +12V
7 NC NC +3.3V NC NC +3.3V
8 GND GND JTAG TMS GND GND -12V
9 NC NC NC NC NC +3.3V
10 GND GND JTAG TDO GND GND GA 0
11 TX0 TX0 - BIST (PULLED
UP)
NC NC +3.3V
12 GND GND GA 1 GND GND PRESENT
13 NC NC NC NC NC +3.3V
14 GND GND GA 2 GND GND I2C DATA
15 NC NC NC NC NC +3.3V
16 GND GND MVMRO
(PULLED
DOWN)
GND GND I2C CLOCK
17 NC NC NC NC NC NC