MOTLoad Commands
MOTLoad Firmware Package User’s Manual (6806800C24D)
80
3.1.28 ds
Name
ds—provides access to the one-line disassembler. By default, the memory location to
disassemble PowerPC assembly instructions is the User Download Buffer.
Synopsis
ds [-a] [-n]
Parameters
-a Ph: Disassembly Address (Default = User Download Buffer)
-n Pd: Number of Instructions (Default = 8)
Example
The following example indicates a typical display when using the ds command.
MOTLoad> ds -a00560000 -n2
00560000 80630000 lwz r3,0x0(r3)
00560004 00000000 word 0x00000000
Error Messages
Assembler Error: error code = <value>
Error code not in table.
Assembler Error: An Operand has a Length of Zero
Self explanatory.
Assembler Error: Unknown Mnemonic
Self explanatory.
Assembler Error: Excessive Operand(s)
Self explanatory.