MOTLoad Commands
MOTLoad Firmware Package User’s Manual (6806800C24D)
223
3.1.124 vmeCfg
Name
vmeCfg—manages user specified VME Configuration parameters. It does this by allowing the
user to create/edit, show, and delete VME configuration parameters. These parameters are
used at start-up time to configure the VME device. If user specified VME Configuration
parameters do not exist, default values are be used instead.
Note: The VME Configuration parameters created by this utility are stored in NVRAM as Global
Environment Variables.
Note: The board must be reset for the values set/changed by vmeCfg to take effect.
Synopsis
vmeCfg [-d] [-e] [-iPd] [-m] [-oPd] [-rPh] [-s] [-z]
Parameters
-d O : Delete User Setting
-e O : Edit/Create User Setting
-i Pd: Inbound Window Number (0-7)
-m O : Master Enable
-o Pd: Outbound Window Number (0-7)
-r Ph: Vme Chip Requester Offset (184/188/400/404/40C/F70)
-s O : Show User/Default Setting
-v O : Verbose Mode
-z O : Restore Default Settings
Example
The following example indicates a typical display when using the vmeCfg command.
MOTLoad> vmeCfg -e -o3
MOTLoad> vmeCfg -s -r40c
MOTLoad> vmeCfg -d -i2
MOTLoad> vmeCfg -z