Artesyn ViewCheck on PrAMC-7311 Installation and Use (May User Manual Page 77

  • Download
  • Add to my manuals
  • Print
  • Page
    / 94
  • Table of contents
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 76
Commands Execution
ViewCheck on PrAMC-7311 Installation and Use (6806800S45C)
77
<Value>Threshold Value</Value>
</Argument>
</InvokeMethod>
</Script>]]>]]>
The following table provides the set-upper-threshold-info command arguments.
5.4.8 set-threshold-default
set-threshold-default command is used to reset the threshold value to default value of
a particular monitor.
Syntax for CLI
set-threshold-default monitorId <Monitor ID> deviceInstance <Dev
Instance>
Syntax for XML
<Script>
<InvokeMethod>
<Object>
<Class>deviceCategory</Class>
<Name>vee0-{Dev Cat}</Name>
</Object>
<Method>setThresholdDefault</Method>
<Argument>
<Name>deviceInstance</Name>
<Value>Dev Instance</Value>
</Argument>
Table 5-21 set-upper-threshold-info
Argument Data Type Description
Monitor ID Integer Type the unique ID of the Monitor for which you want to
set the upper threshold value
Dev Instance Enum Use list-device-instances CLI command to get the
equivalent enumerated value of supported Device
Instance
Threshold Value Integer Type a threshold value for the specified monitor ID