Using HPI-B
System Management Interface Based on BBS HPI-B 2.0 (Centellis 4620/4440) User’s Guide (6806800P21D)
48
4.4.3.3 HPI Domain Events
Depending on the connection status, the Domain Connection sensor can throw events. The
following table provides details.
Category SAHPI_EC_AVAILABILITY
EventCtrl SAHPI_SEC_PER_EVENT
Events SAHPI_ES_ON_LINE | SAHPI_ES_OFF_LINE
Ignore SAHPI_FALSE
DataFormat - ReadingFormats SAHPI_SRF_EVENT_STATE
DataFormat - IsNumeric SAHPI_FALSE
DataFormat - IsThreshold SAHPI_FALSE
Oem 0
Table 4-9 Domain Connection Sensor Reading
SaHpiSensorReadingT Value
ValuesPresent SAHPI_SRF_EVENT_STATE
EventStatus - SensorStatus SAHPI_SENSTAT_EVENTS_ENABLED |
SAHPI_SENSTAT_SCAN_ENABLED
AssertEvents SAHPI_ES_ON_LINE for a connection to a shelf
SAHPI_ES_OFF_LINE when there is no
connection to a shelf
Table 4-8 Domain Connection Sensor (continued)
SaHpiSensorRecT Value
Table 4-10 Domain Connection Sensor Events
Event Description
SAHPI_ES_OFF_LINE No connection
SAHPI_ES_ON_LINE Connection is established. Only now is the
domain of the shelf accessible.